15 wks to JAMB

Alternative to Practical · A4

Back titration: purity of an impure sample

Aim

To determine the percentage purity of an impure sample of calcium carbonate using a double (back) titration.

Apparatus

  • Burette (50 cm³) and stand
  • Pipette (25.0 cm³) and filler
  • Conical flasks
  • White tile
  • Standard (excess) HCl solution, 0.600 mol/dm³
  • Standard NaOH solution for the back titration, 0.0500 mol/dm³
  • Impure solid sample (CaCO₃)
  • Methyl orange or phenolphthalein indicator
  • Weighing balance
  • 250 cm³ volumetric flask

Theory

In a back (double) titration, a known excess of one standard reagent (here acid) is added to react completely with the sample, and the unreacted excess is then found by titrating with a second standard reagent (here base).

The acid that reacted with the sample is found by difference: total moles of acid added − moles of acid left unreacted = moles of acid that reacted. The method suits a sample that does not dissolve completely, reacts slowly, or whose endpoint is otherwise hard to detect directly. CaCO₃ + 2HCl → CaCl₂ + H₂O + CO₂.

How the examiner marks it

  • The sample weighed accurately and its exact mass recorded.
  • A measured excess (not just enough) of standard HCl added; the mixture warmed to complete the reaction, then cooled to room temperature.
  • The solution and its washings made up to 250 cm³ in a volumetric flask, dropwise to the mark, and mixed.
  • 25.0 cm³ portions back-titrated with standard NaOH; the usual titration precautions; concordant titres and their average.
  • Moles of NaOH, hence HCl left unreacted (scaled to 250 cm³), HCl that reacted by subtraction, moles and mass of CaCO₃.
  • The percentage purity of the sample.

The lab

1 · React the sample with excess acid

Weigh the impure calcium carbonate accurately. React it with a measured excess of standard HCl, 50.0 cm³ of 0.600 mol/dm³, warming gently so that it reacts completely. Cool to room temperature, transfer to a 250 cm³ volumetric flask with the washings, make up to the mark with distilled water and mix.

Zero the balance with the empty weighing bottle on it.

0.0000g

◀ All Chemistry practicals